Track record

A 300-unit condo in Selangor, since 2023

We installed two chargers in August 2023. Use has grown every year since, and in 2026 the committee signed for two more.

6.6× More use than the first year. 19.5 hours a day in 2026, up from 2.9 in 2023.
Hours a day the chargers are in use, both chargers combined
  1. 2.9 hours a day2023, Aug to Dec
  2. 6.6 hours a day2024
  3. 11.5 hours a day2025
  4. 19.5 hours a day2026, Jan to Jul

Source: charging app session records, August 2023 to July 2026. Two chargers can give at most 48 hours a day.

August 2023 to July 2026

3,432Charging sessions recorded from August 2023 to July 2026.
83%Of evening hours (6 pm to 11 pm) in 2026, at least one charger was in use.
2 → 4Chargers. The committee approved two more in 2026, on the same zero-cost terms.

Supply

Dynamic load balancing

Our real case: a 100 A supply, four 22 kW chargers with dynamic load balancing. At full power each 22 kW charger draws 32 A on three phases, so four would draw 128 A, more than the 100 A supply. Load balancing shares the supply between the cars that are charging: with all four in use, each still gets 25 A, about 17 kW.

The chargers share the supply automatically. When several cars charge at once, each one slows down a little so the total always stays within the building's limit.

Try the supply planner

For management committees and building owners

How it works for your building

You give us the parking bays. We take care of the chargers, the licence, the app and the upkeep, and send your share every month.

Talk to us about your car park

We visit, check your supply and parking, and send a proposal your committee can decide on.